-40%
Honeywell Jade Conversion Kit W7220 w/ MS3103J1030 Actuator & Temp Sensor
$ 263.97
- Description
- Size Guide
Description
Honeywell Jade Conversion KitHoneywell Jade Conversion Kit W7220 w/ MS3103J1030 Actuator & Temp Sensor
New
Honeywell Jade Conversion Kit W7220 w/ MS3103J1030 Actuator & Temp Sensor
is in New condition.
Please Check All Photos For Everything Included!!
Product Details:
Honeywell Jade Motor W7220A 1000
An economizer control for rooftop HVAC units with series 72 (2-10VDC) actuators for damper control. Occupied/unoccupied mode, exhaust fan mode. Demand Control ventilation when used with 2-10VDC CO-2 sensor.
Honeywell, Inc. MS3103J1030 ZELIX SYLK ACT 27 LB-IN 0
ZELIX SYLK ACT 27 LB-IN 0
• Brushless DC submotor with electronic stall protection on all models
• Self-centering shaft adaptor (shaft coupling) for wide range of shaft sizes
• Access cover to facilitate connectivity
• Durable plastic housing with built-in mechanical end limits
• Spring return direction field selectable
• Shaft position indicator and scale
• UL (cUL) listed and CE compliant
• All models are plenum rated per UL873
Rotation to Open
By switch
Overview
The MS3103 is a 27 lb-in (3Nm), spring return direct-coupled, 24 Vac/dc actuator that accepts Sylk-enabled control for use with the JADE Economizer.
Actuator Type
Damper
Application Type
HVAC
Torque/Force (lb-in., lbf)
27 lb-in.
Feedback
Sylk-enabled
Torque/Force (Nm, N)
3 Nm
Supply Voltage
24 Vac/dc
Fail Safe Mode
Spring Return
Number of Internal Auxiliary Switch
0
Control Signal
Sylk-enabled
Temperature Ratings (Shipping)(F)
.-40 F to +150F
Temperature Ratings (Shipping)(C)
.-40 C to +65 C
List Price
455
Ingress Protection Rating
IP54
Shaft Adapter Type
Self-centering clamping
Manual operation
N/A
Spring Return Torque/Force (lb-in., lbf)
27 lb-in
Spring Return Torque/Force (Nm, N)
3 Nm
Maximum Stall Torque/Force (lb-in., lbf)
70 lb-in.
Maximum Stall Torque/Force (Nm, N)
8 Nm
Rotational Stroke
95 ±3 degrees
Rotational Stroke Adjustment
Mechanically limited 5 degree increments
Spring Return Direction
By orientation
Timing, Maximum Spring Return (sec)
25 sec
Timing, Nominal Driving @ 60 Hz (sec)
90 sec
Compatible Damper Shafts (in.)
3/8 to 5/8 in. round or 1/4 to 1/2 in. square
Frequency
60 Hz
Compatible Damper Shafts (mm)
9 to 16 mm round or 6 to 13 mm square
Materials
Plenum rated plastic housing
External Auxiliary Switches Available
No
Power Consumption (Driving)
6/3 VA
Mounting
Direct Coupled
Dimensions (in.)
6 81/54 high x 3 55/84 wide x 3 5/32 deep
Electrical Connections
Enclosed screw terminal strip (22 to 14 AWG)
Temperature Range, Ambient (F)
.-40 F to +149F
Dimensions (mm)
177 mm high x 98 mm wide x 80 deep
Temperature Range, Ambient (C)
.-40 C to +65 C
Temperature Range, Storage (F)
.-40 F to +150F
Temperature Range, Storage (C)
.-40 C to +65 C
Maximum Noise Rating, Driving (dB(A) @ 1m)
40
Maximum Noise Rating, Holding (dB(A) @ 1m)
20 (no audible noise)
Environmental Rating
NEMA2
Approvals, Canadian Underwriters Laboratories
cUL C22.2 No. 24-93
Weight (lb)
3.5 lb
Approvals, CE
EMC 2004/108/EC; Certification Low Voltage Directive 2006/95/EC; IEC 60730-1 and Part 2-14
Weight (kg)
1.6 kg
Operating Humidity Range (% RH)
5 to 95% RH, non-condensing
Approvals, C-Tick
N314
Approvals, Underwriters Laboratories Inc
UL 873
Honeywell Enthalpy Sensor C7400S1000 for W7220
Digital enthalpy (humidity/temperature) sensor for use with S-Bus devices and W7220 economizer controller.
Features:
This unit mounted C7400S enthalpy sensor includes solid state temperature and humidity sensors. Outputs a digital communicating signal on a two-wire Sylkbus communications link, reporting the temperature and humidity separately to the controller.
The controller determines the enthalpy (total heat), enabling economizer modes of operation when outside air enthalpy is suitable for free cooling.
Enthalpy sensors are compatible with Honeywell economizer systems.
When used with an economizer, the enthalpy boundary curve is programmed via the controller. When the temperature and humidity are determined to be suitable based on the relationship to the boundary, the controller allows outside air for economizing.
Ambient temperature operating range from -40° to 150° F.
Dual enthalpy sensors in outside air and return switches the controllers to economizer mode of operation anytime the outside enthalpy is less than the return air enthalpy.
UL recognized component (Guide info XAPX).
Payment Policy
We require immediate payment.
We accept all major credit cards through PayPal Checkout.
Customers please note: You do not have to have a PayPal account to pay for an item. When eBay directs you to the PayPal payment page, you will be able to insert only the credit card information.
Taxes and charges are not included in the item price or shipping charges. Sales tax will be applied to applicable states. These charges are the buyer's responsibility.
Shipping Policy
Free
USPS/ Fedex Ground shipping for
48 continental states
.
USPS shipping for Hawaii, Alaska, Puerto Rico, APO and P.O. Box address is additional, please email us for quotes.
We ship most items same or next business day after receiving the payment. Please be aware that weekends are not business days.
At our discretion large or expensive packages (0.00) or over will receive signature confirmation. If this applies to you, please assure that an adult is available to sign for & accept the shipment.
We ship everything professionally in our state of the art warehouse, boxed and shipped with perfection.
We ship overseas.
We ship nationwide.
International buyers please note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyers responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/ buying.
Returns policy
If you have any problems with your order, please take the time to email us before leaving a LOW STAR RATING or OPENING A CASE/ CLAIM! We have a 14 day return policy. We refund all shipping cost on defective/ incorrect items.
1. Changed your mind and don't want the item anymore? No problem. You have 14 business days from receipt to inform us of the return request and 5 days to ship it back to us. 15% Restocking fee applies.
2. Defective/ Dead items will be fully refunded or replaced after matching the serial number with the one in our records.
3. Non defective items must be never used or unopened for a refund.
4. Order/ bid cancellation: We can cancel your order only if you contact us within 1 hour after your purchase/ bid.
5. Refunds for returns of non-defective items with FREE SHIPPING, will be LESS because of seller's shipping expense. You will be responsible for shipping the unit back and the shipping that was PAID to ship the unit to you.
2021 - CS WHOLESALE, LLC